Mercurial > repos > chemteam > gmx_solvate
view solvate.xml @ 18:ebcef04f4a78 draft
"planemo upload for repository https://github.com/galaxycomputationalchemistry/galaxy-tools-compchem/tree/master/tools/gromacs commit c428519a27419b62de0556f5beecc4bb7c187ad0"
author | chemteam |
---|---|
date | Tue, 30 Nov 2021 15:28:59 +0000 |
parents | 9a1e472aa515 |
children | 2dfcf594c838 |
line wrap: on
line source
<tool id="gmx_solvate" name="GROMACS solvation and adding ions" version="@TOOL_VERSION@+galaxy@GALAXY_VERSION@"> <description>to structure and topology files</description> <macros> <import>macros.xml</import> <token name="@GALAXY_VERSION@">1</token> </macros> <expand macro="requirements" /> <command detect_errors="exit_code"><![CDATA[ ln -s '$ions' ./ions.mdp && ln -s '$gro_input' ./gro_input.gro && ln -s '$top_input' ./top_input.top && gmx solvate -cp ./gro_input.gro -cs ${water_model}.gro -o solv.gro -p ./top_input.top &>> verbose.txt && gmx grompp -f ./ions.mdp -c solv.gro -p ./top_input.top -o ions.tpr @MAXWARN_CMD@ &>> verbose.txt #if $neutralise or $conc: ## else this step would do nothing && echo 'SOL' | gmx genion -s ions.tpr -o solv_ions.gro -p ./top_input.top -pname NA -nname CL $neutralise -conc $conc -seed $seed &>> verbose.txt && mv solv_ions.gro solv.gro #end if ]]></command> <configfiles> <!-- .mdp file for the gromacs simulation --> <configfile name="ions"> ; Parameters are not so important here as no simulation is run integrator = steep emtol = 1000.0 emstep = 0.01 nsteps = 1 nstlist = 1 cutoff-scheme = Verlet ns_type = grid coulombtype = cutoff rcoulomb = 1.0 rvdw = 1.0 pbc = xyz </configfile> </configfiles> <inputs> <param argument="gro_input" type="data" format='gro' label="GRO structure file"/> <param argument="top_input" type="data" format='top' label="Topology (TOP) file"/> <param name="water_model" type="select" label="Water model for solvation" help="Note SPC is a generic equilibrated 3-point solvent model and can be used as the solvent configuration for any of SPC, SPC/E, or TIP3P water."> <option value="spc216" selected="true">SPC (generic three-point model)</option> <option value="tip4p">TIP4P (four-point model)</option> <option value="tip5p">TIP5P (five-point model)</option> </param> <param name="neutralise" label="Add ions to neutralise system?" type="select" help="If system is charged, replace an appropriate number of randomly selected solvent molecules with sodium or chloride ions to neutralise it."> <option value="-neutral">Yes, add ions</option> <option value="">No</option> </param> <param argument="conc" type="float" value="0" min="0" max="6" label="Specify salt concentration (sodium chloride) to add, in mol/liter" help="Note existing ions in the system are not taken into account - including those added if the neutralise option is selected. Ions are added by randomly replacing water molecules." /> <param argument="seed" type="integer" value="1" min="0" label="Random seed for adding ions" help="Select a random seed for replacing solvent with ions. Set to 0 to generate a seed." /> <expand macro="maxwarn" /> <expand macro="log" /> </inputs> <outputs> <data name="output1" format="gro" from_work_dir="solv.gro" label="GROMACS solvation (GRO) on ${on_string}"/> <data name="output2" format="top" from_work_dir="./top_input.top" label="GROMACS solvation (TOP) on ${on_string}"/> <expand macro="log_outputs" /> </outputs> <tests> <test> <param name="gro_input" value="newbox.gro" /> <param name="neutralise" value="-neutral" /> <param name="top_input" value="topol.top" /> <param name="water_model" value="spc216" /> <param name="conc" value="1" /> <output name="output1" ftype="gro"> <!-- file is big, thus we do not compare the whole file --> <assert_contents> <has_text text="1.671 1.591 3.533"/> <has_text text="2.032 2.417 1.345"/> <has_text text="3.438 1.662 0.307"/> <has_text text="2218CL"/> <has_text text="2147NA"/> </assert_contents> </output> <output name="output2" ftype="top"> <assert_contents> <has_line line="SOL 2130" /> <has_line line="NA 41" /> <has_line line="CL 43" /> </assert_contents> </output> </test> <test> <param name="gro_input" value="newbox.gro" /> <param name="neutralise" value="" /> <param name="top_input" value="topol.top"/> <param name="water_model" value="spc216" /> <param name="conc" value="0" /> <output name="output1" ftype="gro"> <assert_contents> <has_text text="1.671 1.591 3.533"/> <has_text text="2.032 2.417 1.345"/> <has_text text="3.438 1.662 0.307"/> <not_has_text text="2218CL"/> </assert_contents> </output> </test> </tests> <help><![CDATA[ .. class:: infomark **What it does** This tool solvates a system prior to a GROMACS simulation. In addition, sodium or chloride ions can be added if necessary to ensure the system is charge-neutral. _____ .. class:: infomark **Input** - GRO structure file. - Topology (TOP) file. In addition, a water model must be selected - this should be consistent with the one selected previously in the system setup. _____ .. class:: infomark **Output** - GRO structure file. ]]></help> <expand macro="citations" /> </tool>