1 <tool id="lookup_library" name="RIQC-Lookup RI for CAS numbers in library" version="1.0.2">
2 <description>Lookup or estimate the RI using a "known RI values" CAS numbers library</description>
3 <command interpreter="python">
4 library_lookup.py
5 $library_file
6 $input
7 "$col_type"
8 "$polarity"
9 $output
10 #for $ctype in $pref
11 ${ctype.columntype}
12 #end for
13 $regression.model
14 </command>
15 <inputs>
16 <!-- Regarding the <page> items: this blocks the use of this tool in Galaxy workflows. However,
17 alternatives like wrapping this in conditionals, repeats (to force a refresh_on_change as this option
18 is not working on its own) failed since the workflow editor does not support refreshes...not does the
19 workflow runtime support conditionals or repeats to be set at runtime. See also
20 galaxy-dev mail thread "when else" in <conditional> ? RE: refresh_on_change : is this a valid attribute? Any other ideas/options??" -->
21 <page>
22 <param format="tabular" name="input" type="data" label="NIST identifications as tabular file"
23 help="Select a tab delimited NIST metabolite identifications file (converted from PDF)" />
24 <param name="library_file" type="select" label="CAS x RI Library file"
25 help="Select a library/lookup file containing RI values for CAS numbers on various chromatography columns "
26 dynamic_options='get_directory_files("tool-data/shared/PRIMS-metabolomics/RI_DB_libraries")'/>
27 </page>
28 <page>
29 <param name="col_type" type="select" label="Select column type" refresh_on_change="true"
30 display="radio" dynamic_options='get_column_type(library_file)'
31 help="" />
32 </page>
33 <page>
34 <param name="polarity" type="select" label="Select polarity" refresh_on_change="true"
35 display="radio" dynamic_options='filter_column(library_file,col_type)'
36 help="" />
37 </page>
38 <page>
39 <conditional name="regression">
40 <param name="regression_select" type="boolean" checked="false" label="Apply regression method"
41 help="If no data for the selected column is present in the database, selecting this option will try
42 to convert Retention Indices using data from other GC-columns with a regression method. Please
43 note that only the first given GC-column above will be used for this, any alternatives will be
44 ignored" />
45 <when value="true">
46 <param name="model" format="tabular" type="data" label="Tabular file containing regression model"
47 help="This file contains the coefficients used to perform the regression from one GC-column
48 to another GC-column"/>
49 </when>
50 <when value="false">
51 <param name="model" type="hidden" value="False" />
52 </when>
53 </conditional>
54 <repeat name="pref" title="Select column name preference">
55 <param name="columntype" type="select" label="Column name" refresh_on_change="true"
56 dynamic_options='filter_column2(library_file, col_type, polarity)'
57 help="Select one or more column names for filtering. The order defines the priority." />
58 </repeat>
59 </page>
60 </inputs>
61 <outputs>
62 <data format="tabular" label="${tool.name} on" name="output" />
63 </outputs>
64 <code file="match_library.py" />
65 <help>
66 Performs a lookup of the RI values by matching CAS numbers from the given NIST identifications file to a library.
67 If a direct match is NOT found for the preferred column name, a regression can be done to find
68 the theoretical RI value based on known RI values for the CAS number on other column types (see step 4).
69 If there is no match for the CAS number on any column type, then the record is not given a RI.
70
71
72
73 </help>
74